Fluke 1623-2-KIT Analog Output Modules
Item NO.:
Fluke 1623-2-KITGoods Stock:
3Payment:
T/TProduct Origin:
USAColor:
NewShipping Port:
ChinaLead Time:
2-3daysWeight:
0.55kgBrand:
FlukeFluke 1623-2-KIT Analog Output Modules
Product Description:
Fluke Analog Output Modules are high-precision instruments engineered primarily for calibration, testing, and automated data acquisition systems. Known for their laboratory-grade accuracy in rugged industrial form factors, these modules convert digital commands from a control computer or main logging unit into precise, continuous electrical analog signals. They are widely used as reference standards to calibrate field instruments, simulate industrial processes, and drive proportional control mechanisms with exceptional stability and minimal thermal drift.
The technical profile of a Fluke Analog Output Module emphasizes metrological precision, low noise, and stable signal generation:
Output Signal Types: Provides highly linear DC voltage (e.g., 0V to 10V, -10V to +10V) and DC current (e.g., 0mA to 20mA, 4mA to 20mA) standard outputs.
Digital-to-Analog Resolution: Equipped with high-resolution D/A converters, typically 16-bit to 18-bit, allowing for microvolt and microampere level adjustment steps.
Basic Accuracy: Extremely tight tolerance limits, with typical voltage accuracy specifications hovering around 0.01 percent to 0.02 percent of the output range.
Temperature Coefficient: Superior thermal stability, often specified at less than 5 ppm per degree Celsius, ensuring consistent performance despite ambient temperature changes.
Channel Isolation: Features comprehensive galvanic isolation, often rated up to 1500V AC between channels and to the system chassis, preventing ground loops.
Settling Time: Fast response capabilities, with output stabilization settling times typically under 100 microseconds for full-scale voltage steps.
Fluke Analog Output Modules stand out due to their strict adherence to metrological standards and rugged design:
Metrology-Grade Precision: Designed by a leader in calibration technology, these modules offer unmatched repeatability and accuracy, making them suitable as traceable calibration references.
Advanced Safety Isolation: The robust channel-to-channel isolation safeguards sensitive laboratory control systems from high-voltage transients present on the industrial field side.
Smart Self-Calibration: Many models support automated internal calibration checks against onboard stable voltage references, extending the required external calibration interval.
Low Total Harmonic Distortion: Generates clean, low-noise waveforms that prevent interference when testing sensitive electronic components or simulating complex sensor outputs.
Seamless Integration: Designed to fit into Fluke data acquisition frameworks, enabling automated test procedures when paired with specialized software.
These modules are extensively applied in environments where measurement certainty and precise simulation are paramount:
Sensor and Transmitter Calibration: Acting as a highly accurate signal source to calibrate industrial pressure, temperature, and flow transmitters.
Loop Simulation Testing: Simulating 4-20mA control loops to verify the configuration and response of distributed control systems (DCS) and programmable logic controllers (PLCs).
Research and Development: Serving as a variable, low-noise power or signal source in laboratories to test prototype hardware under specific electrical conditions.
Valve and Actuator Positioning: Providing precision control signals to command proportional valves and electronic dampers during automated mechanical testing.
Quality Assurance Automation: Integrated into final-stage factory test benches to automatically source exact reference voltages to newly manufactured electronic products.
To maintain the exceptional accuracy of the module and ensure operator safety, the following operating principles must be followed:
Strict Grounding Protocols: Ensure that the guard and shield terminals are correctly connected according to the system configuration to prevent ambient electromagnetic noise from corrupting the high-precision output signal.
Load Impedance Matching: Adhere strictly to the maximum load resistance limits for current outputs and minimum load resistance limits for voltage outputs. Overloading the circuit will cause the module to saturate or display error codes.
Warm-Up Periods: For high-precision calibration tasks, always allow the module to run and stabilize thermally for the period specified by the manufacturer, typically between 15 and 30 minutes.
Safe Maintenance Scheduling: Disconnect all external field connections before removing the module from its main housing unit to avoid electrical shocks or damaging the internal backplane interface pins.
Calibration Traceability: Annual recalibration at an authorized metrology lab is vital. Operating the module beyond its calibrated expiration date will compromise measurement traceability and product validation data.
The structure and details of the product:

Our services:
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Warranty: one year
Please make an inquiry for more models:
Fluke TIS75
Fluke MS2-100
Fluke 718EX300G
Fluke 754
MAGNETEK WH1D-2FF
MAGNETEK 3D53-18-1 3D53181
MAGNETEK GPD506V-B014
CAREL NTC060WP00-C
STEGO RC016
Uni-T UT204
Uni-T UTi260B
Sanwa CD-800A
Burkert 8225
Hoffman DAH4002B
Hoffman EGK030
HOCHIKI DCD-AE3
HOCHIKI SOC-24VN
Endress+Hauser PMC131-A11F1A1S
Endress+Hauser FTW325-A2A1A
Endress+Hauser FXA195
Endress+Hauser CLM253-CD0005
Endress+Hauser CLS21-C1E4A+50088280
Endress+Hauser FMU90-R11CA111AA1A
Endress+Hauser FMU30-AAHEABGHF
Endress+Hauser CLS21-C2A4A
JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. JUSTWELL PTE. LTD. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.
This article is from the official website of JUSTWELL PTE. LTD. If reprinted, please attach this link: https://justwellltd.com .com
JUSTWELL PTE. LTD
Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.

Tags :