PXI-5600 National Instruments Analog Output Modules
Item NO.:
PXI-5600 National InstrumentsGoods Stock:
3Payment:
T/TProduct Origin:
USAColor:
NewShipping Port:
ChinaLead Time:
2-3daysWeight:
0.55kgBrand:
National InstrumentsPXI-5600 National Instruments Analog Output Modules
Product Description:
National Instruments (NI) Analog Output Modules, primarily belonging to the C Series, PXI, or PXI Express hardware families, are high-performance instruments designed to convert digital values from a controller into precise, continuous electrical voltage or current signals. These modules are widely used in advanced test, measurement, and control applications where they drive external devices such as actuators, power supplies, valves, and motor amplifiers, or simulate various sensor outputs for hardware-in-the-loop (HIL) testing.
The technical baseline of an NI Analog Output module focuses on timing precision, resolution, and signal fidelity:
Channel Density: Available in flexible configurations ranging from 2, 4, 8, to 16 independent output channels per module.
Output Ranges: Supports standard bipolar and unipolar ranges including ±10V, ±5V, 0V to 10V, and current loops such as 0mA to 20mA or 4mA to 20mA.
Digital-to-Analog Resolution: Features high-precision conversion, typically utilizing 16-bit or 18-bit DACs to ensure minimal quantization error and ultra-fine step adjustments.
Update Rate: Ranges from standard static output modules up to high-speed waveform generation modules capable of updating at several megasamples per second (MS/s) per channel.
Isolation Architecture: Built-in channel-to-earth ground or channel-to-channel isolation options, often rated up to 250V RMS continuous or 60V DC bank isolation.
Output Current Drive: Voltage outputs are typically capable of sourcing and sinking around ±10mA to ±20mA per channel, providing sufficient power to drive standard high-impedance loads.
NI Analog Output modules are highly favored in research, development, and production testing due to their timing flexibility and software integration:
Deterministic Synchronization: When paired with PXI chassis backplanes or CompactRIO chassis, these modules can share a common timing clock, allowing analog outputs to be synchronized perfectly with input channels down to the nanosecond level.
Onboard Regeneration and Buffering: High-speed modules feature internal FIFO memory buffers, allowing complex waveforms to be loaded once and regenerated continuously without relying on the host computer's processor.
Software-Defined Flexibility: Fully supported by the NI-DAQmx driver framework and LabVIEW, enabling engineers to change output ranges, update rates, and generation modes via software configurations rather than manual hardware adjustments.
Advanced Overvoltage Protection: Equipped with robust output protection circuits that safeguard the module against accidental short circuits to ground or overvoltage connections from external power sources.
High Linearity and Low Noise: Engineered with strict adherence to low total harmonic distortion (THD) and low noise floors, making them ideal for high-fidelity signal simulation.
These modules are essential tools in automated test environments and rapid prototyping setups:
Hardware-in-the-Loop Simulation: Simulating the electrical behavior of temperature, pressure, or position sensors to test and validate Electronic Control Units (ECUs) in aerospace and automotive industries.
Control Loop Prototyping: Acting as the control signal output stage in custom proportional-integral-derivative (PID) systems, regulating proportional valves or heating elements.
Power Supply Control: Sending automated voltage commands to programmable DC or AC power supplies during automated component testing or burn-in processes.
Acoustic and Vibration Stimulation: Generating precise analog waveforms to drive audio amplifiers, shakers, or acoustic transducers for environmental stress screening.
Semiconductor Validation: Providing clean reference voltages and bias currents to test device characteristics during wafer or packaged-die characterization.
To maintain the absolute accuracy of the generated signals and protect the module from damage, users must follow these operation protocols:
Load Impedance Awareness: Always check the minimum load impedance specification of the module's voltage output. Connecting a load that demands more current than the channel can source will cause voltage clipping and trigger internal overcurrent protection.
Proper Shielding and Grounding: Use shielded twisted-pair cabling for signal routing and ground the shield at only one point—preferably at the NI chassis side. Ground loops can introduce significant offset errors and noise into the analog signal.
Power-On State Management: Be aware of the module's default power-on or glitch states. When the chassis boots up or resets, the analog output may briefly output a small voltage spike, which could prematurely trigger highly sensitive downstream actuators.
Cable Length Constraints: For high-speed waveform generation, keep cables as short as possible to minimize capacitive loading. Excessive cable capacitance can degrade the signal's rise time and cause oscillation on the output line.
Calibration Intervals: To maintain the specified absolute accuracy, ensure the module is calibrated within its recommended calibration interval (typically 1 or 2 years) using NI's calibration software utilities.
The structure and details of the product:

Our services:
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Warranty: one year
Please make an inquiry for more models:
National Instruments PXIE-7976R
National Instruments PXIE-8135
National Instruments PXIE-8840
National Instruments SCB-68A
National Instruments SCB-100A
National Instruments SCXI-1120D
National Instruments SCXI-1162
National Instruments SCXI-1162HV
National Instruments SCXI-1302
National Instruments SCXI-1326
National Instruments SCXI-1327
National Instruments SHC68-68-EPM
National Instruments PXI-5421
National Instruments PXI-2529
National Instruments PXI-8331
National Instruments SCXI-1600
National Instruments PXI-7841R
National Instruments NI9250
National Instruments PCI-6238
National Instruments SH68-68-D1
National Instruments pxie-6358
National Instruments cb-68lpr
National Instruments pci-6034e
National Instruments 9982
National Instruments USB-6210
National Instruments SH68-68-D1
National Instruments pxi-2533
National Instruments pxi-7344
National Instruments pci-6229
National Instruments PXIe-7820R
National Instruments 9252
National Instruments 187965G-01L
National Instruments 9220
National Instruments 9403
National Instruments 9862
National Instruments PXI-6030E
National Instruments 9233
National Instruments PCI-6221
National Instruments 9421
National Instruments SCXI-1163
National Instruments 9146 782445-01
National Instruments 9237 780264-01
National Instruments 9205 785184-01
National Instruments 9514
National Instruments 192061-02
National Instruments CRIO-9030
National Instruments cRIO-9012
National Instruments PXIE-4163
National Instruments 9264
National Instruments 9235
National Instruments PXI-2569
National Instruments PCI-6602
National Instruments OPT22 PCI-AC51
National Instruments PXIE-4300
National Instruments pxie-1078
National Instruments pxie-6361
National Instruments pxi-2586
National Instruments PXI-4072
National Instruments pxle-2524
National Instruments PCI-5421
National Instruments PCI-6033E
National Instruments pxie-2524
National Instruments SH160DIN-4XDB50F
National Instruments 160pin DIN
National Instruments pxi-6704
National Instruments PXI-7953R
National Instruments PCLE-6321
National Instruments 9923
National Instruments PXIE-8880
National Instruments PCI-8430/8
National Instruments PCI-6225
National Instruments PXIE-7846
National Instruments USB-6218
National Instruments 9201
National Instruments PXLE-4302
National Instruments PCIE-7841R
National Instruments PXIE-6378
National Instruments PXIE-4302
National Instruments PXIE-4339
National Instruments PXI-6229
National Instruments USB-6363
National Instruments CDAQ-9178
National Instruments 9211
National Instruments SCXI-1325
National Instruments 192809B-01
National Instruments PXLE-1078
National Instruments PXLE-8821
National Instruments PXLE-4139
National Instruments PCI-6503
National Instruments CDAQ-9188
National Instruments SHC68-C68-RDIO
National Instruments PCI-1200
National Instruments PXI-6221
National Instruments PCle-6323
National Instruments PXI-4065
National Instruments PXLE-4339
National Instruments PXIE-4310
National Instruments PCI-4065
National Instruments TBX-50
National Instruments USB-5132
National Instruments PXIE-5644R
National Instruments 5540
National Instruments PXIE-2790
National Instruments PXIE-1075
National Instruments PCI-6703
National Instruments GPIB-RS232
JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. JUSTWELL PTE. LTD. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.
This article is from the official website of JUSTWELL PTE. LTD. If reprinted, please attach this link: https://justwellltd.com .com
JUSTWELL PTE. LTD
Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.
