PXI-2586 National Instruments Power Board
Item NO.:
PXI-2586 National InstrumentsGoods Stock:
3Payment:
T/TProduct Origin:
USAColor:
NewShipping Port:
ChinaLead Time:
2-3daysWeight:
0.55kgBrand:
National InstrumentsPXI-2586 National Instruments Power Board
Product Description:
National Instruments (NI) Power Boards, often integrated into PXI chassis, CompactRIO storage systems, or industrial controller backplanes, are high-efficiency power management modules. These boards are responsible for regulating, filtering, and distributing clean DC power from a main input source to sensitive measurement circuitry, data acquisition modules, and FPGA processors. They are engineered to minimize electrical noise and thermal dissipation, ensuring the highest level of measurement accuracy for instrumentation systems.
The technical parameters of National Instruments Power Boards focus on voltage stability, ripple suppression, and power density:
Input Voltage Range: Commonly accepts wide-range DC inputs such as 9V to 30V DC for mobile/embedded applications, or standard AC grid inputs for benchtop chassis systems.
Internal DC Rails: Delivers precisely regulated multiple output voltages including 3.3V, 5V, 12V, and -12V DC to power different layers of backplane electronics.
Output Ripple and Noise: Exceptionally low ripple voltage, typically under 50 millivolts peak-to-peak, to prevent high-frequency noise from bleeding into analog measurement channels.
Efficiency Rating: Advanced synchronous rectification topologies achieve energy conversion efficiencies up to 92 percent, reducing internal cabinet heat buildup.
Power Capacity: Continuous power output ratings generally range from 30W for compact embedded systems to over 300W for multi-slot instrumentation chassis.
Overvoltage Protection: Integrated hardware clamping thresholds that trigger safety shutdowns if output rails exceed 115 percent of their nominal voltage.
NI Power Boards provide critical advantages for high-performance testing and measurement environments:
Low Electromagnetic Interference: Designed with extensive multi-layer shielding and optimized component placement to meet strict automated test equipment (ATE) emissions standards.
Intelligent Power Monitoring: Features onboard telemetry circuits that track real-time voltage levels, current draw, and temperature statistics, accessible via NI software tools like LabVIEW.
Power Sequencing Control: Automatically manages the startup and shutdown timing of different voltage rails to prevent latch-up conditions in high-speed FPGAs and processors.
Transient Response Resilience: Capable of recovering rapidly from sudden current spikes caused by high-speed digital switching without dropping voltage regulation.
Ruggedized Thermal Design: Utilizes internal copper thermal planes and structural heatsinks to dissipate heat efficiently, eliminating the need for loud cooling fans in lower-wattage deployments.
These power boards serve as the foundation for stable data acquisition across numerous engineering fields:
Automated Test Equipment: Powering PXI instrumentation stacks used for semiconductor validation, circuit board testing, and consumer electronics quality control.
Embedded Control and Monitoring: Providing reliable power to CompactRIO systems deployed on heavy machinery, wind turbines, and smart grid monitoring nodes.
Automotive Research: Distributing power within in-vehicle data logging systems used for advanced driver-assistance systems (ADAS) testing and crash validation.
Aerospace and Defense: Supporting telemetry and hardware-in-the-loop (HIL) simulation racks where continuous power uptime is mission-critical.
Laboratory Instrumentation: Activating high-precision analog input and output chassis used in university research and structural health monitoring.
To preserve the accuracy of adjacent measurement hardware and prevent power failure, the following instructions must be observed:
Input Polarity Verification: Always double-check the polarity of the DC input wiring before applying power. Reverse polarity can cause terminal damage to the input protection diodes.
Common-Mode Noise Grounding: Ensure the chassis ground point of the power board is tied directly to a clean instrument earth ground. Inadequate grounding will compromise the noise floor of nearby analog-to-digital converters.
Clearance and Airflow: Maintain the specified mechanical clearance around the power board vents. Blocking airflow will elevate the internal temperature, shortening the lifespan of the electrolytic filtering capacitors.
Derating for Temperature: When operating the system in ambient environments above 50 degrees Celsius, reduce the maximum allowable power draw according to the official thermal derating curves.
Safe Discharge Time: High-capacity capacitors on the board retain electrical energy for a short duration after power-off. Wait at least 60 seconds before removing the board or altering internal connections to avoid minor shocks or component damage.
The structure and details of the product:

Our services:
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Warranty: one year
Please make an inquiry for more models:
National Instruments PXIE-7976R
National Instruments PXIE-8135
National Instruments PXIE-8840
National Instruments SCB-68A
National Instruments SCB-100A
National Instruments SCXI-1120D
National Instruments SCXI-1162
National Instruments SCXI-1162HV
National Instruments SCXI-1302
National Instruments SCXI-1326
National Instruments SCXI-1327
National Instruments SHC68-68-EPM
National Instruments PXI-5421
National Instruments PXI-2529
National Instruments PXI-8331
National Instruments SCXI-1600
National Instruments PXI-7841R
National Instruments NI9250
National Instruments PCI-6238
National Instruments SH68-68-D1
National Instruments pxie-6358
National Instruments cb-68lpr
National Instruments pci-6034e
National Instruments 9982
National Instruments USB-6210
National Instruments SH68-68-D1
National Instruments pxi-2533
National Instruments pxi-7344
National Instruments pci-6229
National Instruments PXIe-7820R
National Instruments 9252
National Instruments 187965G-01L
National Instruments 9220
National Instruments 9403
National Instruments 9862
National Instruments PXI-6030E
National Instruments 9233
National Instruments PCI-6221
National Instruments 9421
National Instruments SCXI-1163
National Instruments 9146 782445-01
National Instruments 9237 780264-01
National Instruments 9205 785184-01
National Instruments 9514
National Instruments 192061-02
National Instruments CRIO-9030
National Instruments cRIO-9012
National Instruments PXIE-4163
National Instruments 9264
National Instruments 9235
National Instruments PXI-2569
National Instruments PCI-6602
National Instruments OPT22 PCI-AC51
National Instruments PXIE-4300
National Instruments pxie-1078
National Instruments pxie-6361
National Instruments pxi-2586
National Instruments PXI-4072
National Instruments pxle-2524
National Instruments PCI-5421
National Instruments PCI-6033E
National Instruments pxie-2524
National Instruments SH160DIN-4XDB50F
National Instruments 160pin DIN
National Instruments pxi-6704
National Instruments PXI-7953R
National Instruments PCLE-6321
National Instruments 9923
National Instruments PXIE-8880
National Instruments PCI-8430/8
National Instruments PCI-6225
National Instruments PXIE-7846
National Instruments USB-6218
National Instruments 9201
National Instruments PXLE-4302
National Instruments PCIE-7841R
National Instruments PXIE-6378
National Instruments PXIE-4302
National Instruments PXIE-4339
National Instruments PXI-6229
National Instruments USB-6363
National Instruments CDAQ-9178
National Instruments 9211
National Instruments SCXI-1325
National Instruments 192809B-01
National Instruments PXLE-1078
National Instruments PXLE-8821
National Instruments PXLE-4139
National Instruments PCI-6503
National Instruments CDAQ-9188
National Instruments SHC68-C68-RDIO
National Instruments PCI-1200
National Instruments PXI-6221
National Instruments PCle-6323
National Instruments PXI-4065
National Instruments PXLE-4339
National Instruments PXIE-4310
National Instruments PCI-4065
National Instruments TBX-50
National Instruments USB-5132
National Instruments PXIE-5644R
National Instruments 5540
National Instruments PXIE-2790
National Instruments PXIE-1075
National Instruments PCI-6703
National Instruments GPIB-RS232
JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. JUSTWELL PTE. LTD. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.
This article is from the official website of JUSTWELL PTE. LTD. If reprinted, please attach this link: https://justwellltd.com .com
JUSTWELL PTE. LTD
Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.
