PCIE-6351 National Instruments
PCIE-6351 National Instruments
PCIE-6351 National Instruments

PCIE-6351 National Instruments

PCIE-6351  National Instruments Filter Modules

  • Item NO.:

    PCIE-6351 National Instruments
  • Goods Stock:

    3
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Shipping Port:

    China
  • Lead Time:

    2-3days
  • Weight:

    0.55kg
  • Brand:

    National Instruments

PCIE-6351 National Instruments Filter Modules

Product  Description

National Instruments (NI) Filter Modules, integrated within platform systems such as PXI, PXI Express (PXIe), and C Series (CompactDAQ/CompactRIO), are specialized analog signal conditioning units designed to remove noise, prevent aliasing, and shape electrical signals before digitization. These modules provide critical front-end analog processing, including low-pass, high-pass, and band-pass filtering, ensuring the integrity of high-speed data acquisition systems used in structural test, acoustics, vibration, and RF applications.

Product Parameters

The technical characteristics of NI Filter and Signal Conditioning Modules vary depending on the platform but typically match the following performance criteria:

  • Cutoff Frequency Range: Fully programmable via software, ranging from less than 1 Hz up to several hundred kilohertz, or tens of megahertz for RF-specific filtering modules.

  • Filter Order and Architecture: Features high-order analog filter topologies, such as 4-pole, 6-pole, or 8-pole Butterworth, Bessel, or Elliptic filters, ensuring steep roll-off characteristics.

  • Anti-Aliasing Attenuation: Delivers high rejection rates, often exceeding 80 dB to 100 dB at the stopband, effectively preventing out-of-band signals from distorting sample measurements.

  • Channel Density: Modular layouts commonly offer 2, 4, 8, or 16 independent analog channels per slot to align with multi-sensor deployment.

  • Input Voltage Range: Configurable differential or single-ended inputs capable of handling signals up to plus or minus 10V or greater, with built-in programmable gain amplifiers.

  • Phase Match Precision: Tight inter-channel phase matching, typically within 1 degree or less, which is critical for simultaneous sampling and spatial orientation calculations.

Product Advantages

NI Filter Modules stand out in the automated test industry due to their hardware-software synchronization and precise analog designs:

  • Real-Time Anti-Aliasing Protection: Automatically scales filter cutoff frequencies based on the active sampling rate, ensuring foolproof protection against high-frequency spectral overlapping.

  • Software-Defined Programmability: Fully manageable through the NI-DAQmx driver framework and LabVIEW environment, allowing users to modify filter types, cutoff points, and gains on-the-fly without changing physical components.

  • Noise and Ripple Reduction: Significantly reduces wideband background noise and power-line interference, maximizing the signal-to-noise ratio (SNR) and dynamic range of connected digitizers.

  • Flexible Signal Conditioning Integration: Often combines filtering with other essential conditioning features such as sensor excitation (for IEPE accelerometers or strain gauges), AC/DC coupling, and differential amplification.

  • Scalable Modular Footprint: Fits into standardized compact chassis, enabling engineers to construct highly customized, high-channel-count setups alongside other specialized test instruments.

Product Applications

These modules are deployed extensively in precision measurement and high-fidelity testing environments:

  • Sound and Vibration Analysis: Filtering high-frequency noise from microphones, hydrophones, and accelerometers in NVH (Noise, Vibration, and Harshness) testing.

  • Structural Health Monitoring: Eliminating structural vibrations and electrical noise when measuring mechanical stress, fatigue, and strain on bridges, aircraft wings, and wind turbines.

  • Aerospace and Defense Testing: Conditioning dynamic telemetry data, engine acoustics, and structural impact signals during rigorous system validation processes.

  • Biomedical Engineering: Preamplifying and filtering low-frequency, low-amplitude physiological signals like ECG or EEG from ambient electromagnetic fields.

  • RF and Wireless Communication: Attenuating harmonic distortions and adjacent channel emissions in software-defined radio (SDR) and radar prototyping platforms.

Important Precautions

To preserve signal clarity and prevent hardware degradation, users must observe the following technical guidelines:

  • Ground Loop Prevention: Use differential wiring whenever possible for analog sensor inputs and ensure proper shielding, as ground loops can introduce common-mode noise that bypasses filter baselines.

  • Insertion Loss Adjustment: Be aware that analog active filters can introduce small insertion losses or DC offsets. Utilize NI-DAQmx calibration functions to zero out offsets prior to running critical test routines.

  • Phase Shift Considerations: High-order filters inherently introduce frequency-dependent phase delays. When evaluating timing relationships across different channels, account for this delay or use linear-phase Bessel filters.

  • Thermal Stabilization: To achieve specified filtering precision and minimize component drift, allow the module and its host chassis to run and thermally stabilize for at least 15 to 30 minutes before taking data.

  • Live Swapping Constraints: Always reference the specific C Series or PXI module manual regarding hot-swapping. While many modern NI architectures support live module changes, sudden insertion into a faulty backplane slot can compromise logic state settings.

The structure and details of the product

Our services

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Warrantyone year

Please make an inquiry for more models:

National Instruments PXIE-7976R

National Instruments PXIE-8135 

National Instruments PXIE-8840

National Instruments SCB-68A  

National Instruments SCB-100A

National Instruments SCXI-1120D 

National Instruments SCXI-1162 

National Instruments SCXI-1162HV

National Instruments SCXI-1302 

National Instruments SCXI-1326

National Instruments SCXI-1327 

National Instruments SHC68-68-EPM 

National Instruments PXI-5421

National Instruments PXI-2529

National Instruments PXI-8331

National Instruments SCXI-1600

National Instruments PXI-7841R

National Instruments NI9250

National Instruments PCI-6238

National Instruments SH68-68-D1

National Instruments pxie-6358

National Instruments cb-68lpr

National Instruments pci-6034e

National Instruments 9982

National Instruments USB-6210

National Instruments SH68-68-D1

National Instruments pxi-2533

National Instruments pxi-7344

National Instruments pci-6229

National Instruments PXIe-7820R

National Instruments 9252

National Instruments 187965G-01L

National Instruments 9220

National Instruments 9403

National Instruments 9862

National Instruments PXI-6030E

National Instruments 9233

National Instruments PCI-6221

National Instruments 9421

National Instruments SCXI-1163

National Instruments 9146 782445-01

National Instruments 9237 780264-01

National Instruments 9205 785184-01

National Instruments 9514

National Instruments 192061-02

National Instruments CRIO-9030

National Instruments cRIO-9012

National Instruments PXIE-4163

National Instruments 9264

National Instruments 9235

National Instruments PXI-2569

National Instruments PCI-6602

National Instruments OPT22 PCI-AC51

National Instruments PXIE-4300

National Instruments pxie-1078

National Instruments pxie-6361

National Instruments pxi-2586

National Instruments PXI-4072

National Instruments pxle-2524

National Instruments PCI-5421

National Instruments PCI-6033E

National Instruments pxie-2524

National Instruments SH160DIN-4XDB50F

National Instruments 160pin DIN

National Instruments pxi-6704

National Instruments PXI-7953R

National Instruments PCLE-6321

National Instruments 9923

National Instruments PXIE-8880

National Instruments PCI-8430/8

National Instruments PCI-6225

National Instruments PXIE-7846

National Instruments USB-6218

National Instruments 9201

National Instruments PXLE-4302

National Instruments PCIE-7841R

National Instruments PXIE-6378

National Instruments PXIE-4302

National Instruments PXIE-4339

National Instruments PXI-6229

National Instruments USB-6363

National Instruments CDAQ-9178

National Instruments 9211

National Instruments SCXI-1325

National Instruments 192809B-01

National Instruments PXLE-1078

National Instruments PXLE-8821

National Instruments PXLE-4139

National Instruments PCI-6503

National Instruments CDAQ-9188

National Instruments SHC68-C68-RDIO

National Instruments PCI-1200

National Instruments PXI-6221

National Instruments PCle-6323

National Instruments PXI-4065

National Instruments PXLE-4339

National Instruments PXIE-4310

National Instruments PCI-4065

National Instruments TBX-50

National Instruments USB-5132

National Instruments PXIE-5644R

National Instruments 5540

National Instruments PXIE-2790

National Instruments PXIE-1075

National Instruments PCI-6703

National Instruments GPIB-RS232

JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. JUSTWELL PTE. LTD. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.

This article is from the official website of JUSTWELL PTE. LTD. If reprinted, please attach this link: https://justwellltd.com .com

JUSTWELL PTE. LTD

Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.

 

Leave A Message
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

National Instruments PXI-7953R
National Instruments PXI-7953R
National Instruments PXI-7953R Power module
National Instruments 9866
National Instruments 9866
National Instruments 9866 Power module
SH68-68-D1 National Instruments
SH68-68-D1 National Instruments
SH68-68-D1 National Instruments Central control module
PXIE-8840 National Instruments
PXIE-8840 National Instruments
PXIE-8840 National Instruments Central control module
National Instruments PXie-2586
National Instruments PXie-2586
National Instruments PXie-2586 Power module
CDAQ-9181 National Instruments
CDAQ-9181 National Instruments
CDAQ-9181 National Instruments Input module
PXI-6030E National Instruments
PXI-6030E National Instruments
PXI-6030E National Instruments Input module
PXI-5402 National Instruments
PXI-5402 National Instruments
PXI-5402 National Instruments Input module

Leave A Message

Leave A Message
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for News?
Contact Us #
+8613348389590

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

whatsApp

contact