PCI-6289 National Instruments Filter Modules
Item NO.:
PCI-6289 National InstrumentsGoods Stock:
3Payment:
T/TProduct Origin:
USAColor:
NewShipping Port:
ChinaLead Time:
2-3daysWeight:
0.55kgBrand:
National InstrumentsPCI-6289 National Instruments Filter Modules
Product Description:
National Instruments (NI) Filter Modules, integrated within platform systems such as PXI, PXI Express (PXIe), and C Series (CompactDAQ/CompactRIO), are specialized analog signal conditioning units designed to remove noise, prevent aliasing, and shape electrical signals before digitization. These modules provide critical front-end analog processing, including low-pass, high-pass, and band-pass filtering, ensuring the integrity of high-speed data acquisition systems used in structural test, acoustics, vibration, and RF applications.
The technical characteristics of NI Filter and Signal Conditioning Modules vary depending on the platform but typically match the following performance criteria:
Cutoff Frequency Range: Fully programmable via software, ranging from less than 1 Hz up to several hundred kilohertz, or tens of megahertz for RF-specific filtering modules.
Filter Order and Architecture: Features high-order analog filter topologies, such as 4-pole, 6-pole, or 8-pole Butterworth, Bessel, or Elliptic filters, ensuring steep roll-off characteristics.
Anti-Aliasing Attenuation: Delivers high rejection rates, often exceeding 80 dB to 100 dB at the stopband, effectively preventing out-of-band signals from distorting sample measurements.
Channel Density: Modular layouts commonly offer 2, 4, 8, or 16 independent analog channels per slot to align with multi-sensor deployment.
Input Voltage Range: Configurable differential or single-ended inputs capable of handling signals up to plus or minus 10V or greater, with built-in programmable gain amplifiers.
Phase Match Precision: Tight inter-channel phase matching, typically within 1 degree or less, which is critical for simultaneous sampling and spatial orientation calculations.
NI Filter Modules stand out in the automated test industry due to their hardware-software synchronization and precise analog designs:
Real-Time Anti-Aliasing Protection: Automatically scales filter cutoff frequencies based on the active sampling rate, ensuring foolproof protection against high-frequency spectral overlapping.
Software-Defined Programmability: Fully manageable through the NI-DAQmx driver framework and LabVIEW environment, allowing users to modify filter types, cutoff points, and gains on-the-fly without changing physical components.
Noise and Ripple Reduction: Significantly reduces wideband background noise and power-line interference, maximizing the signal-to-noise ratio (SNR) and dynamic range of connected digitizers.
Flexible Signal Conditioning Integration: Often combines filtering with other essential conditioning features such as sensor excitation (for IEPE accelerometers or strain gauges), AC/DC coupling, and differential amplification.
Scalable Modular Footprint: Fits into standardized compact chassis, enabling engineers to construct highly customized, high-channel-count setups alongside other specialized test instruments.
These modules are deployed extensively in precision measurement and high-fidelity testing environments:
Sound and Vibration Analysis: Filtering high-frequency noise from microphones, hydrophones, and accelerometers in NVH (Noise, Vibration, and Harshness) testing.
Structural Health Monitoring: Eliminating structural vibrations and electrical noise when measuring mechanical stress, fatigue, and strain on bridges, aircraft wings, and wind turbines.
Aerospace and Defense Testing: Conditioning dynamic telemetry data, engine acoustics, and structural impact signals during rigorous system validation processes.
Biomedical Engineering: Preamplifying and filtering low-frequency, low-amplitude physiological signals like ECG or EEG from ambient electromagnetic fields.
RF and Wireless Communication: Attenuating harmonic distortions and adjacent channel emissions in software-defined radio (SDR) and radar prototyping platforms.
To preserve signal clarity and prevent hardware degradation, users must observe the following technical guidelines:
Ground Loop Prevention: Use differential wiring whenever possible for analog sensor inputs and ensure proper shielding, as ground loops can introduce common-mode noise that bypasses filter baselines.
Insertion Loss Adjustment: Be aware that analog active filters can introduce small insertion losses or DC offsets. Utilize NI-DAQmx calibration functions to zero out offsets prior to running critical test routines.
Phase Shift Considerations: High-order filters inherently introduce frequency-dependent phase delays. When evaluating timing relationships across different channels, account for this delay or use linear-phase Bessel filters.
Thermal Stabilization: To achieve specified filtering precision and minimize component drift, allow the module and its host chassis to run and thermally stabilize for at least 15 to 30 minutes before taking data.
Live Swapping Constraints: Always reference the specific C Series or PXI module manual regarding hot-swapping. While many modern NI architectures support live module changes, sudden insertion into a faulty backplane slot can compromise logic state settings.
The structure and details of the product:

Our services:
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Warranty: one year
Please make an inquiry for more models:
National Instruments PXIE-7976R
National Instruments PXIE-8135
National Instruments PXIE-8840
National Instruments SCB-68A
National Instruments SCB-100A
National Instruments SCXI-1120D
National Instruments SCXI-1162
National Instruments SCXI-1162HV
National Instruments SCXI-1302
National Instruments SCXI-1326
National Instruments SCXI-1327
National Instruments SHC68-68-EPM
National Instruments PXI-5421
National Instruments PXI-2529
National Instruments PXI-8331
National Instruments SCXI-1600
National Instruments PXI-7841R
National Instruments NI9250
National Instruments PCI-6238
National Instruments SH68-68-D1
National Instruments pxie-6358
National Instruments cb-68lpr
National Instruments pci-6034e
National Instruments 9982
National Instruments USB-6210
National Instruments SH68-68-D1
National Instruments pxi-2533
National Instruments pxi-7344
National Instruments pci-6229
National Instruments PXIe-7820R
National Instruments 9252
National Instruments 187965G-01L
National Instruments 9220
National Instruments 9403
National Instruments 9862
National Instruments PXI-6030E
National Instruments 9233
National Instruments PCI-6221
National Instruments 9421
National Instruments SCXI-1163
National Instruments 9146 782445-01
National Instruments 9237 780264-01
National Instruments 9205 785184-01
National Instruments 9514
National Instruments 192061-02
National Instruments CRIO-9030
National Instruments cRIO-9012
National Instruments PXIE-4163
National Instruments 9264
National Instruments 9235
National Instruments PXI-2569
National Instruments PCI-6602
National Instruments OPT22 PCI-AC51
National Instruments PXIE-4300
National Instruments pxie-1078
National Instruments pxie-6361
National Instruments pxi-2586
National Instruments PXI-4072
National Instruments pxle-2524
National Instruments PCI-5421
National Instruments PCI-6033E
National Instruments pxie-2524
National Instruments SH160DIN-4XDB50F
National Instruments 160pin DIN
National Instruments pxi-6704
National Instruments PXI-7953R
National Instruments PCLE-6321
National Instruments 9923
National Instruments PXIE-8880
National Instruments PCI-8430/8
National Instruments PCI-6225
National Instruments PXIE-7846
National Instruments USB-6218
National Instruments 9201
National Instruments PXLE-4302
National Instruments PCIE-7841R
National Instruments PXIE-6378
National Instruments PXIE-4302
National Instruments PXIE-4339
National Instruments PXI-6229
National Instruments USB-6363
National Instruments CDAQ-9178
National Instruments 9211
National Instruments SCXI-1325
National Instruments 192809B-01
National Instruments PXLE-1078
National Instruments PXLE-8821
National Instruments PXLE-4139
National Instruments PCI-6503
National Instruments CDAQ-9188
National Instruments SHC68-C68-RDIO
National Instruments PCI-1200
National Instruments PXI-6221
National Instruments PCle-6323
National Instruments PXI-4065
National Instruments PXLE-4339
National Instruments PXIE-4310
National Instruments PCI-4065
National Instruments TBX-50
National Instruments USB-5132
National Instruments PXIE-5644R
National Instruments 5540
National Instruments PXIE-2790
National Instruments PXIE-1075
National Instruments PCI-6703
National Instruments GPIB-RS232
JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. JUSTWELL PTE. LTD. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.
This article is from the official website of JUSTWELL PTE. LTD. If reprinted, please attach this link: https://justwellltd.com .com
JUSTWELL PTE. LTD
Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.